The module is protected by fuses from excessive loads and short circuits. When necessary, the negative potential can be jumpered to other devices through the output.
A properly functioning module is indicated via a LED (green) at the output.
![]() 81.000.3010.0 [Schematic] |
|
| Input | |
| Nominal voltage | 115 VAC/230 VAC +6%/-10% |
| Nominal current | at 115VAC, ca. 450 mA at 230VAC, ca. 225 mA |
| Input fuse (5x20mm) | at 115VAC, 0.5A at 230VAC, 0.25A |
| Disconnect voltage, I/O | 4 kV |
| Output | |
| Nominal voltage | 24VDC +/- 5% |
| Nominal current | max. 1A |
| Ripple | ca. 20 mV |
![]() 87.230.1553.0 [Schematic] |
|
| Input | |
| Nominal voltage | 115 VAC/230 VAC +6%/-10% |
| Input fuse (5x20mm) | at 115VAC, 0.8A at 230VAC, 0.4A |
| Output | |
| Capacity | max. 60 VA |
| Nominal voltage | 10V - 18V - 21V - 24V AC |
| Nominal current | max. 2.5A |
![]() [Schematic] |
|
| Part Number | 81.000.3000.0 |
| Input | |
| Voltage | 115V/230V AC +6/- 10% |
| Current | 100 mA at 115V, 50 mA at 230V |
| Rated power | 8 VA |
| Output | |
| Voltage | 24VDC |
| Current | 300 mA |
| Ripple | <2 Vss |
| Output fuse | 300 mA |
| Isolation voltage | 4 kV eff. 50 Hz, 1 min. |
| Operating temp. | -25C...(see derating curve) |
| Storage temp | -25C...+85C |